Interpretation Response #PI-70-0110 ([Manufacturers Standardization Society of the Valve & Fittings Industry] [Mr. Robert V. Warrick])
Below is the interpretation response detail and a list of regulations sections applicable to this response.
Interpretation Response Details
Response Publish Date:
Company Name: Manufacturers Standardization Society of the Valve & Fittings Industry
Individual Name: Mr. Robert V. Warrick
Location State: VA Country: US
View the Interpretation Document
Response text:
PI-70-0110
November 9, 1970
Mr. Robert V. Warrick
Executive Secretary
Manufacturers Standardization Society
of the Valve & Fittings Industry
1815 North Fort Myer Drive
Arlington, Virginia 22209
Dear Mr. Warrick:
This is in reply to your request for an interpretation of 49 CFR, Section 192.149 concerning the requirements for butt-welding fittings. You ask if there is compliance with the requirements of Section 192.149(b) if -
(1) Manufacturers will certify that prototype burst testing has been done to establish lines of fittings and
(2) Manufacturers will document field test experience on fittings representative of size, thickness and material strength to a pressure as high as required for the pipeline to which it is being added.
The first sentence of Section 192.149(b) is taken from the ANSI B31.8 Code, Section 831.31(b) except that the Code references to ANSI B16.9, MSS SP-48 and MSS SP-63 have been omitted. The second sentence of Section 1-2.140 is a restatement of the requirements for a bursting strength test as provided for by ANSI B16.9 paragraph 8 by MSS SP-48 paragraph 8.
The practice described in your letter meet the requirements of Section 192.149(b) provided that the steel butt-welding fittings being tested also have temperature ratings based on stresses for pipe of the same or equivalent material.
If we can be of further assistant, please do not hesitate to ask.
Sincerely,
Joseph C. Caldwell
Director, Acting
Office of Pipeline Safety
Regulation Sections
| Section | Subject |
|---|---|
| 192.149 | Standard fittings |