USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Portions of the Department of Transportation are currently in shutdown/furlough status due to a lapse in appropriations. Please continue to monitor this page for updates on DOT’s operating status.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #11-0188 ([Riceland Foods, Inc.] [Mr. Neil Washburn])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Riceland Foods, Inc.

Individual Name: Mr. Neil Washburn

Location State: AR Country: US

View the Interpretation Document

Response text:

September 22, 2011

 

 

Mr. Neil Washburn

Riceland Foods, Inc.

709 East 22nd Street

Stuttgart, AR 72160

Ref. No. 11-0188

Dear Mr. Washburn:

This responds to your August 11, 2011 request for clarification of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). In your email, you describe a material that is a mixture of soybean oil and diatomaceous earth that is classed and described as "UN3088, Self-heating solid, organic, n.o.s., 4.2, PG II." Specifically, you ask if the material in question may be transported in closed, sift-proof, bulk bins in accordance with the packaging authorization of § 173.240.

The answer is yes. The bulk packaging section referenced in column 8 of the table in § 172.101 for "UN3088, Self-heating solid, organic, n.o.s., 4.2, PG II" is § 173.241, however, § 172.101(i)(4) permits the use of packagings authorized for solids in § 173.240 when the material is in the solid form. Section 173.240(c) authorizes the use of sift-proof closed bulk bins. It is your responsibility to ensure that, in accordance with § 173.24(b), the package is designed, constructed, maintained, filled, its contents so limited, and closed to prevent release of the material.

I hope this answers your inquiry. If you need additional assistance, please contact this office at (202) 366-8553.

Sincerely,

Ben Supko

Acting Chief, Standards Development

Standards and Rulemaking Division

172.101, 173.240, 173.24(b)