USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #99-0166 ([Albemarle Corporation] [Jack E. Helms, Ph.D, P.E])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Albemarle Corporation

Individual Name: Jack E. Helms, Ph.D, P.E

Location State: LA Country: US

View the Interpretation Document

Response text:

August 25, 2000

 

Jack E. Helms, Ph.D, P.E.               Ref No. 99-0166
Advisor, Transportation
Albemarle Corporation
451 Florida Street
Baton Rouge, LA 70801-1780

Dear Dr. Helms:

I apologize for the delay in responding to your letter concerning the requirement in 49 CFR 173.31(d)(1)(vi) to carefully inspect a frangible (rupture) disc in a pressure relief device prior to each hazardous material shipment.  This requirement has its origins in regulations of the Interstate Commerce Commission issued in 1921. As you noted, the wording of this requirement was most recently revised in a final rule published on September 21, 1995, under RSPA's Docket Nos.  Hm- I 75A and 201 (60 Fed.  Reg. 49098).

The language of § 173.31 (d)(1)(vi) states the purpose of this type of inspection is to check "for corrosion or damage that may alter the intended operation of the device."  For that reason in response to a comment submitted in a separate rule-making proceeding under Docket No.HM-216(61 Fed.Reg.28666,28671; June 5, 1996), we stated in the preamble that RSPA and FRA believe in order to fully inspect a rupture disc (both top and bottom), the disc must be removed from the safety vent device.  It has been FRA's experience that a rupture disc may appear normal on the top side, but be severely damaged or corroded on the bottom side.

You and others have raised concerns about the language of the present rule and its application to persons that forward a loaded tank car received from another location or return a tank car with residue. We anticipate initiating a rule-making in the near future to address these concerns.

Sincerely,

 

Edward T. Mazzullo
Director, Office of Hazardous
Materials Standards