USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #98-0576 ([Hazmat Guru Consulting] [Mr. H.J. Pace])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Hazmat Guru Consulting

Individual Name: Mr. H.J. Pace

Location State: TX Country: US

View the Interpretation Document

Response text:

JUN 26, 1998

Mr. H.J. Pace

President, CEO

Hazmat Guru Consulting

6917 Kirkwood Road

Fort Worth, TX 76116-9420

Dear Mr. Pace:

This is in response to your letter requesting clarification of quantity limits for carriage on cargo-only aircraft of hazardous materials in inaccessible cargo compartment. I apologize for the delay in responding.

Your questions have been paraphrased and answered as follows:

Question 1. How much hazardous material acceptable for passenger or cargo aircraft may be transported in an inaccessible cargo compartment or freight container?

Passenger authorized hazardous materials that are carried aboard passenger aircraft in inaccessible compartments are limited by 49 CFR 175.75(a)(2)(D to 25 kg. of hazardous materials (reference to the Division 2.2 limit will be omitted for the sake of simplicity) per compartment, whether in a freight container or not. Passenger authorized hazardous materials carried aboard cargo-only aircraft in inaccessible compartments or an inaccessible manner within an accessible compartment are limited to 25 kg. of hazardous material per compartment when not in freight containers. If a passenger authorized hazardous material is carried within freight containers in an accessible cargo compartment, they are limited to 25 kg. of hazardous material per freight container.

Question 2. How much cargo-only authorized hazardous materials carried aboard cargo-only aircraft are allowed to be transported in an inaccessible cargo compartment?

The answer is none. Section 175.85(b) prohibits the carriage of hazardous materials

acceptable only for cargo aircraft from being carried in an inaccessible fashion. Except as provided in 49 CFR 175.85(c), hazardous materials prepared for transportation by cargo-only aircraft must always be accessible by the flight crew.

Your inquiry highlights some of the difficulty which has been experienced in interpreting §§ 175.75 and 175.85. We are currently examining all of the provisions of 49 CFR Part 175, and intend to correct discrepancies in a future rulemaking.

I trust this satisfies your inquiry. If this Office can be of further assistance, please contact us.

Sincerely,

Edward T. Mazzullo

Director, Office of Hazardous

Materials Standards