Interpretation Response #09-0287 ([Corporate EH & S Engineer Sika Corporation] [Mr. Felix H. Wawra])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Corporate EH & S Engineer Sika Corporation

Individual Name: Mr. Felix H. Wawra

Location State: NJ Country: US

View the Interpretation Document

Response text:

January 15, 2010

 

 

 

Mr. Felix H. Wawra

Corporate EH & S Engineer

Sika Corporation

201 Polito Avenue

Lyndhurst, NJ 07071

Ref. No. 09-0287

Dear Mr. Wawra:

This responds to your December 1, 2009 request for clarification of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). Specifically, you ask if the excepted quantity marking in §173.4a applies to transportation by all modes.

The answer is yes. The excepted quantity marking in §173.4a applies to all modes of transportation. However, excepted quantities of hazardous materials packaged in accordance with this section may not be carried in checked or carry-on baggage aboard aircraft.

I hope this answers your inquiry. If you need additional assistance, contact this Office at 202-366-8553.

Sincerely,

Charles E. Betts

Chief, Standards Development

Office of Hazardous Materials Standards

173.4a

Regulation Sections

Section Subject
173.4a Excepted quantities