Interpretation Response #08-0269 ([PDT Packaging, Design & Testing, LLC] [Mr. Chris Weigert])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: PDT Packaging, Design & Testing, LLC

Individual Name: Mr. Chris Weigert

Location State: CT Country: US

View the Interpretation Document

Response text:

October 17, 2011

 

 

 

Mr. Chris Weigert

Engineer

PDT Packaging, Design & Testing, LLC

P.O. Box 64

10 Hazelwood Road

East Granby, CT 06026

Ref. No. 08-0269

Dear Mr. Weigert:

This responds to your letter requesting clarification of the test protocols for UN standard packagings under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). Please accept my apology for our delay in responding and any inconvenience this may have caused. Your questions are paraphrased and answered as follows:

Q1. We operate a DOT- recognized United Nations (UN) Third Party Certification Agency (Assigned Symbol +AV). Must we issue separate unique test report identifications to multiple manufacturers that use the same successfully-tested design?

A1. If your agency issues packaging certifications to more than one manufacturer, as defined in § 178.2(e), a new unique certification number must be issued. For packaging variations issued to the same manufacturer, a single test certification number may be used provided the test report identifies all of the packaging variations represented by that unique number. For example, if a manufacturer"s box design has been tested using three different closure methods, boxes with all three closures may be marked with the same certification number. The test report must indicate that all three closure methods were tested, and all three closure methods must be tested at the time of periodic retesting. Although not recommended, the same certification number may be used for more than one design; however, when using a single certification number for multiple designs, it should only be used to identify similar packaging designs which differ in minor respects. Packaging designs that differ substantially from each other should be described on separate test reports and issued separate certification numbers.

Q2. Must a test report be prepared by a UN Third Party Certification Agency for UN standard packaging designs that fail when tested in accordance with the HMR?



A2. Generally, requirements for test report preparation and their applicability to a DOT- recognized UN Third Party Certification Agency is prescribed under the terms and conditions of the approval authorization issued by this Office. Your company is assigned Approval CA2006070021. Neither the HMR nor your specific approval requires the preparation of a test report for a packaging design that fails the prescribed performance tests.

I trust this satisfies your inquiry. Please contact us if we can be of further assistance.

Sincerely,

T. Glenn Foster

Chief, Regulatory Review and Reinvention Branch

Standards and Rulemaking Division