USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Portions of DOT are affected by a lapse in appropriations. Website information may be outdated, transactions may be delayed, and inquiries may not be answered until funding is restored. Please monitor this page for updates.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #08-0166 ([Remington Arms Company, Inc.] [Mr. Gregory D. Kehrli])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Remington Arms Company, Inc.

Individual Name: Mr. Gregory D. Kehrli

Location State: NC Country: US

View the Interpretation Document

Response text:

Mr. Gregory D. Kehrli
Worldwide Transportation Manager
Remington Arms Company, Inc.
870 Remington Drive
Madison, NC 27025

Ref. No. 08-0166

Dear Mr. Kehrli:

This responds to your June 9, 2008 letter requesting clarification of the requirements for structural serviceability of containers and vehicles carrying Class 1 (explosive) materials on ships under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). Specifically, you ask for clarification of the applicability of the requirements to Division 1.4S explosives under § 176.172 of the HMR.

It is your understanding that Division 1.4 explosives are not subject to the structural serviceability requirements under § 176.172(a)(2) based on the exception from the requirement to have a certification statement of structural serviceability accompany the shipment as provided in § 176.172(c). You indicate that your understanding is supported by language in the International Maritime Dangerous Goods Code (IMDG Code). 7.4.6.4.2 of the IMDG Code states that "freight containers and vehicles shall not be offered for the transport of goods of class 1 other than division 1.4 unless the container or the vehicle is structurally serviceable."

Your understanding is correct. It is the opinion of this Office that Division 1.4 explosives (including Division 1.4S explosives) are excepted from the structural serviceability requirements in accordance with § 176.172(c) of the HMR. According to § 176.172(c), "all shipments of Class 1 (explosive) materials except those in Division 1.4 (explosive) must be accompanied by a statement, which may appear on the shipping paper, certifying that the freight container or the vehicle is structurally serviceable as defined in paragraph (a)(2) of this section."

The intent of § 176.172(c) is to except Division 1.4 explosives from the structural serviceability requirements in the same manner as the IMDG Code. The language as written is unclear and could be interpreted to only except Division 1.4 explosives from the requirement for a certification statement to accompany the shipment. However, the certification statement is not required because the containers or vehicles containing Division 1.4 explosives are not required to meet the structural serviceability requirements of § 176.172(a)(2). We will clarify this language in an upcoming rulemaking.

I hope this information is helpful.

Sincerely,

Susan Gorsky
Acting Chief, Standards Development
Office of Hazardous Materials Standards

176.172

Regulation Sections