USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Portions of the Department of Transportation are currently in shutdown/furlough status due to a lapse in appropriations. Please continue to monitor this page for updates on DOT’s operating status.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #07-0066 ([Network Environmental Systems] [Mr. Earl Thomas])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Network Environmental Systems

Individual Name: Mr. Earl Thomas

Location State: CA Country: US

View the Interpretation Document

Response text:

May 15, 2007

 

Mr. Earl Thomas                 Reference No. 07-0066
Network Environmental Systems
1141 Sibley Street
Folsom, CA 95630

Dear Mr. Thomas:

This is in response to your March 22, 2007 letter requesting clarification of the requirements in the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). Specifically, you inquire about the applicability of the “materials of trade” exceptions.

A “material of trade” is defined as a hazardous material, other than a hazardous waste, that is carried on a motor vehicle: (1) to protect the health and safety of the operator or passengers; (2) to support the operation or maintenance of the motor vehicle, including its auxiliary equipment; or (3) by a private motor carrier (including vehicles operated by a rail carrier) in direct support of a principal business that is other than transportation by motor vehicle.

Your questions are paraphrased and answered as follows:

Q1.      Is § 173.6 applicable to the transport of an aircraft battery (i.e., a lead acid battery) in a motor vehicle, owned and operated by an airline, from an aircraft to a maintenance shop or from an aircraft to a different location for repackaging and subsequent shipment?

Al.        Yes, under the scenario described in the question, the transport of the battery is eligible for “materials of trade” exceptions under § 173.6 because it satisfies the third condition in the definition of a “material of trade.” A hazardous material transported in conformance with § 173.6 is not subject to any other requirements in the HMR besides those set forth or referenced in the section. You should be aware that if the battery is repackaged and transported using a commercial carrier, it is no longer eligible for the “materials of trade” exceptions. Additionally, the transport of the lead acid battery may be eligible for exceptions under § 173.159. Specifically, section 173.159(e) provides that electric storage batteries containing electrolytes are not subject to the HMR for transportation by highway (or rail) provided that no other hazardous materials are transported in the same vehicle; the batteries are loaded and braced so as to prevent damage and short circuits in transit; any other material loaded in the same vehicle must be blocked, braced, or otherwise secured to prevent contact with or damage to the
batteries; and the transport vehicle may not carry material shipped by any person other than the shipper of the batteries.

Q2.      Is § 173.6 applicable to the transport of a life raft (i.e., a “Life-saving appliance”) in a motor vehicle, owned and operated by an airline, from an aircraft to a location for repackaging and subsequent shipment? Would § 173.6 be applicable if a courier was used in place of an airline owned and operated vehicle?

A2.      Yes. A Class 9 material such as a life raft properly classified as a “Life-saving appliance, self inflating,” UN2990, for example, is eligible for “materials of trade” exceptions in § 173.6. The transport of the life raft is not eligible for “materials of trade” exceptions when a commercial carrier (or a contracted driver) is used because this transport does not meet one of the three conditions for defining a “material of trade.”

I hope this information is helpful. Please contact us if you require additional assistance.

Sincerely,

 

John A. Gale
Chief, Standards Development
Office of hazardous Material Standards

173.6, 173.159