USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Portions of the Department of Transportation are currently in shutdown/furlough status due to a lapse in appropriations. Please continue to monitor this page for updates on DOT’s operating status.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #06-0189 ([Nukem Corporation] [Mr. Stan Hodges])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Nukem Corporation

Individual Name: Mr. Stan Hodges

Location State: SC Country: US

View the Interpretation Document

Response text:

Sep 29, 2006

 

Mr. Stan Hodges                 Reference No. 06-0189
Senior Project Manager
Nukem Corporation
3800 Fernandina Road Suite 200
Columbia, SC 29210

Dear Mr. Hodges:

This is in response to your August 15, 2006 letter requesting clarification regarding the applicability of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) to HEPA vents. Your question pertains to § 173.412(f) which requires the containment system to retain its radioactive contents under the reduction of ambient pressure to 25 kPa (3.6 psi). Specifically, you ask if a passive HEPA vent may be installed in a Type A package to meet the pressure requirement in § 173.412(f) as long as the resultant containment system would not release any radioactivity to the environment.

The HMR do not prohibit the use of vents in Type A packagings containing Class 7 (radioactive) materials. However, the packaging must be an authorized packaging for the Class 7 (radioactive) material under the HMR, meet the HMR design specification (if applicable), and comply with the general packaging requirements in Part 173, Subpart B. The Type A packaging, with the vent, must meet the design and construction requirements in § 178.350, which also requires compliance with § 173.403, 173.410, 173.412, 173.415, 173.465 and 173.466.

I hope this information is helpful.

Sincerely,

 

Hattie L. Mitchell, Chief
Regulatory Review and Reinvention
Office of Hazardous Materials Standards

173.412(f)