USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

The Department of Transportation has resumed normal operations

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #02-0292 ([U.S. Geological Survey] [Dr.Stephen R. Moulton])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: U.S. Geological Survey

Individual Name: Dr.Stephen R. Moulton

Location State: VA Country: US

View the Interpretation Document

Response text:

Apr 10, 2003

Dr. Stephen R. Moulton, II                    Reference No. 02-0292
Biological Operations Manager
United States Department of Interior
U.S. Geological Survey
National Water-Quality Assessment Program
Reston, Virginia 20192

Dear Dr. Moulton:

This responds to your letter regarding whether biological samples from streams, preserved with Formalin, are regulated for transportation under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180).  We apologize for the delay in responding and hope it has not caused any inconvenience.

Your agency collects biological samples from streams to determine the identification and abundance of algae and invertebrates (e.g., insects, crustaceans, worms, clams) for use in water-quality studies.  For each sample, the stream bottom material (consisting of organisms and debris) is preserved with either 3-5% formalin (algae samples) or 10% formalin (invertebrate samples).  A single sample container ranges from 60 mL to a maximum of 1L.  These samples are shipped to a central laboratory for analysis.

Section 172.101(c)(11) provides, in part, that a shipper may assign a tentative shipping name, hazard class and identification number to a material sent for testing, based on the shipper's tentative determination according to defining criteria in the HMR, hazard precedence prescribed in § 173.2, and the shipper's knowledge of the material.  Based on the information you provided, it is this Office's opinion that these samples do not meet the definition of an infectious substance in § 173.134 because there is no reason to know or suspect they contain an infectious substance.

Although you did not provide sufficient information, such as a Material Safety Data Sheet, the acute effects of Formaldehyde Solutions has been well documented.  Formalin (10% formaldehyde solution), used to preserve the biological samples, meet the definition for a Class 9 material in § 173.140 and is subject to regulation when transported domestically by air. The appropriate shipping description is "Other Regulated Substances, liquid, n.o.s. (formaldehyde), 9, NA3082, III." Generally, solutions of less than 10% formaldehyde mixed with non-hazardous materials do not meet the definition of a Class 9 hazardous material and, provided they do not meet any other hazard class, are not subject to the HMR. As provided by § 173.22 of the HMR, it is the shipper's responsibility to properly class a hazardous material.  Manufacturers, generally, have the knowledge to properly class the materials and products they produce, although it may be necessary to enlist an outside laboratory to assist in the classification process as testing may have to be conducted to see how a product compares to the criteria for the various hazard classes.

I hope this satisfies your inquiry.  If we can be of further assistance, please contact us.

Sincerely,

Delmer F. Billing
Chief, Standards Division
Office of Hazardous Materials Standards

172.101, 173.134

Regulation Sections