USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #PI-72-030 ([Harco Corporation] [B. Husock, P.E.])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Harco Corporation

Individual Name: B. Husock, P.E.

Location State: OH Country: US

View the Interpretation Document

Response text:

Mr. B. Husock, P.E.

Harco Corporation

Corrosion Engineering Division

4600 East 71st Street

Cleveland, Ohio 44125

Dear Mr. Husock:

This is in reply to your letter dated May 31, 1972, regarding an interpretation of Section 192.467(a), 49 CFR.

Your specific question was regarding Section 192.467(a) which states, in part, "each buried or submerged pipeline must be electrically isolated from other underground metallic structures."

You inquired whether this requirement applied to all gas distribution systems under all circumstances whether or not cathodic protection is eventually applied.

Section 192.467(a) does not apply to all gas distribution systems. It is intended to apply to all new pipelines.

Existing distribution systems are covered by Section 192.467(b), which requires insulation wherever electrical isolation of a portion of a pipeline is necessary to facilitate the application of corrosion control. However, existing distribution lines must be cathodically protected only in areas in which active corrosion is found (Section 192.457(b)(3)). Isolation assures an insulating barrier between metals of different anodic potentials, facilitating corrosion control. Accordingly, electrical isolation of existing distribution lines is not required under all circumstances, but only where necessary to facilitate the application of corrosion control required by Section 192.457(b)(3).

We trust that this will answer your specific question.