USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Portions of the Department of Transportation are currently in shutdown/furlough status due to a lapse in appropriations. Please continue to monitor this page for updates on DOT’s operating status.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #12-0095 ([Guerilla Air] [Mr. Sam Newman])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Guerilla Air

Individual Name: Mr. Sam Newman

Location State: CA Country: US

View the Interpretation Document

Response text:

October 3, 2012

 

 

Mr. Sam Newman
President
Guerilla Air
14111 S. Kingsley Dr.
Gardena, CA 90249

Reference No.: 12-0095

Dear Mr. Newman:

This is in response to your April 12, 2012 e-mail requesting clarification of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). You ask several questions pertaining to the production of aluminum cylinders that do not exceed 4 fluid ounces water capacity, to be used for carbon dioxide service. Your questions are paraphrased and answered as follows:

Q1. How is the maximum water capacity of the cylinders measured?

A1. The maximum water capacity of a cylinder is measured by filling the cylinder to the base of the neck, at the point where the threads inside the neck of the cylinder end and the shoulder of the cylinder begins to flare out away from the neck. The threaded portion of the neck is designed to accept the valve assembly and is not intended to be included in the volumetric capacity of the cylinder.

Q2. In accordance with § 173.306(i), can three of the described individual cylinders be placed in communication with each other using an apparatus (manifold) and be shipped by ground using the ORM-D designation?

A2. Yes, provided certain conditions are met. In accordance with § 173.306(a)(1) and § 173.306(a) respectively, the individual cylinders must not exceed 4 fluid ounces capacity and each package must not exceed 30 kg (66 pounds) gross weight. In addition, to meet the 4 fluid ounce capacity limitation provided by § 173.306(a)(1) each cylinder in the assembly would have to be isolated with a positive restriction or a shutoff valve that remains tightly closed in transit. Also, in accordance with § 172.316(a)(2), as of December 31, 2013, the ORM-D designation will no longer be available for ground transportation. However, in response to a final rule published on January 19, 2011 (HM-215K; 76 FR 3308) that adopted this sunset date for the use of the ORM-D designation, administrative appeals have been filed requesting an additional period of time to continue using this designation. We intend to address these appeals in a future rulemaking.

Q3. Do the described cylinders have to meet the manifolding conditions provided in § 173.301(g) when charged with Division 2.2 carbon dioxide?

A3. The cylinders must meet the manifolding requirements of § 173.301(g). In accordance with § 173.301(g)(1), the Division 2.2 carbon dioxide gas is not subject to the requirement for individual shutoff valves that are securely closed while in transit. However, if the individual cylinders are not isolated as discussed in A2 the limited quantity and ORM-D designation exceptions provided in § 173.306 would not be available.

I trust this satisfies your inquiry. Please contact us if we can be of further assistance.

Sincerely,

 

Delmer Billings
Senior Regulatory Advisor
Standards and Rulemaking Division

173.306, 173.301

Regulation Sections