USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Portions of the Department of Transportation are currently in shutdown/furlough status due to a lapse in appropriations. Please continue to monitor this page for updates on DOT’s operating status.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #05-0290 ([Galls/Aramark Inc.] [Mr. Carl Jackson])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: Galls/Aramark Inc.

Individual Name: Mr. Carl Jackson

Location State: KY Country: US

View the Interpretation Document

Response text:

Mar 24, 2006

 

Mr. Carl Jackson                     Reference No. 05-0290
Galls/Aramark Inc.
2680 Palumbo Drive
P.O. Box 54308
Lexington, KY 40555-4308

Dear Mr. Jackson:

This is in response to your October 31, 2005 letter requesting clarification of the applicability of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) to a freight forwarder who processes international shipments of hazardous materials. Specifically, you ask whether responsibility for compliance with the HMR transfers from the original offeror to the freight forwarder when the shipment is processed by the freight forwarder for international transportation. If not, you ask whether a written agreement between the original offeror and the freight forwarder could relieve the original offeror from its responsibility for compliance with the HMR.

Your question pertains to the following scenario: The original offeror prepares and offers for transportation a shipment of hazardous material classified as Consumer commodity, ORM-D. The shipment is routed through a freight forwarder, who prepares and offers the shipment for international transportation.

Under the HMR, any person who performs a “pre-transportation function” (see definition in § 171.8) is an offeror of hazardous material. Pre-transportation functions are functions performed to prepare a shipment for transportation, including assigning a hazard class to a material, selecting a packaging for the material, filling and closing the packaging, marking and labeling the packaging, and preparing shipping documentation and emergency response information to accompany the shipment. There may be more than one offeror of a shipment of hazardous m Each offeror s responsible for complying ‘with the requirements of the HMR, with respect to any pre-transportation function that it performs or is required to perform; however, each offeror is responsible only for the specific pre-transportation functions that it performs or is required to perform, and each offeror may rely on in provided by another offeror, unless that ofleror knows or, a reasonable person, acting in the circumstances and exercising reasonable care, would have knowledge that the information provided by the other offeror is incorrect.

Your scenario has two parts. For the first part of transportation, the original offeror is responsible for compliance with requirements applicable to the shipment of consumer
commodities under the HMR. For the second part of transportation, both the original offeror arid the freight forwarder are responsible for the pre-transportation functions they perform. For example, if the original offeror prepares the package in the manner to be forwarded to its international destination by the freight forwarder, the original offeror is responsible for compliance with package selection, filling and closure requirements, and package marking and labeling The freight forwarder will be responsible for compliance with packaging requirements if it alters the packaging, places the material in a different packaging, or has reason to believe that the original package (including its markings and labels) is not in compliance with the HMR. If the freight forwarder performs all the required pre-transportation functions applicable to the international portion of transportation - including classifying the material, selecting and filling a packaging, preparing a shipping document, supplying emergency response information, and marking and labeling the package - then the freight forwarder would be solely responsible for assuring the shipment complies with applicable requirements.

Unless the freight forwarder is handling the hazardous materials shipment without relying on information provided by the original offeror, a written agreement to transfer responsibility from the original offeror to the freight forwarder does not relieve the original offeror from its responsibility for the shipment. In your scenario, it appears that the freight forwarder is relying on information you provide to process the shipment for international transportation. If so, you are responsible for the accuracy of the information you provide as well as the requirements applicable to the functions you perform relative to that shipment.

I hope this information is helpful. Please contact us if you require additional assistance.

Sincerely,

 

John A. Gale
Chief, Standards Development
Office of Hazardous Materials Standards

171.1

Regulation Sections