Interpretation Response #03-0128 ([Bioconvergence, Inc.] [Mr. Scott Kobryn])
Below is the interpretation response detail and a list of regulations sections applicable to this response.
Interpretation Response Details
Response Publish Date:
Company Name: Bioconvergence, Inc.
Individual Name: Mr. Scott Kobryn
Location State: NY Country: US
View the Interpretation Document
Response text:
Jul 7, 2003
Mr. Scott Kobryn Reference No. 03-0128
President
Bioconvergence, Inc.
2801 Long Road
Grand Island, New York 14072
Dear Mr. Kobryn:
This responds to your May 13, 2003 letter requesting clarification the applicability of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-1 80) to your magnesium alloy turnings, which are shipped to your plant as “Magnesium alloys, UN 1869, 4.1, PG III” (with more than 50 percent magnesium in pellets, turnings or ribbons). Specifically, you ask if the magnesium alloy solids produced in your recycling process are regulated under the HMR.
According to your letter, after receiving the magnesium alloy turnings, you use a washing and drying process that removes oil and contaminants from the turnings, producing a clean, dry turning. You create magnesium alloy solid shapes from the magnesium alloy turnings in your recycling process using high-pressure briquetting equipment. These clean and dry alloy turnings are compressed into blocks at high pressure to create magnesium alloy solid shapes that are approximately 92% of solid ingot density. The magnesium alloy solids are then shipped to your customers for use as a replacement for magnesium ingot.
You state that the magnesium alloy solids produced by your company no longer meet the defining criteria in Part 173 of the HMR for “Magnesium alloys, UN 1869, 4.1, PG III”. Therefore, you want to ship these magnesium alloy solids as non-hazardous, Recovered Magnesium Alloy Solids. Under § 173.22, the shipper is responsible for assigning the appropriate hazard class for the hazardous material according to the HMR. This Office does not normally perform that function. Based on the information provided in your letter, it is the opinion of this Office that if your recycled magnesium alloy solids in the recycled form no longer meet the defining criteria for Division 4.1 materials or any other hazard class defined in Part 173 of the HMR, and, they are not a hazardous waste, hazardous substance, or marine pollutant, they are not subject to the HMR.
I hope this answers your inquiry.
Sincerely,
Susan Gorsky
Senior Transportation Regulations Specialistt
Office of Hazardous Materials Standards
173.22
Regulation Sections
| Section | Subject |
|---|---|
| 173.22 | Shipper's responsibility |