Interpretation Response #02-0263 ([CHS Cooperatives] [John R. Macpherson])
Below is the interpretation response detail and a list of regulations sections applicable to this response.
Interpretation Response Details
Response Publish Date:
Company Name: CHS Cooperatives
Individual Name: John R. Macpherson
Location State: IA Country: US
View the Interpretation Document
Response text:
Mar 02, 2003
Mr. John R. Macpherson                   Reference No. 02-0263
  Corp. QC Manager
  CHS Cooperatives
  16682B 245th Street
  Mason City, IA  50401
Dear Mr. Macpherson,
This is in response to your September 23, 2002, letter regarding placarding requirements on a cargo tank motor vehicle under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). Specifically, you ask based on the photographs you provided, if you are in violation of 172.516(c)(4).
The placards and markings shown in the provided photographs are not in violation of § 172-516(c)(4). Section 172.516(c)(4) states that the placard must be located away from any markings (such as advertising) that could substantially reduce its effectiveness and in any case at least 3 inches (76.0mm.) away from such marking. The markings displayed next to the placards in the submitted photographs are required by § 172.328 and Special Provision 13. Therefore, § 172.516(c)(4) is not applicable to these markings.
I hope this satisfies your request.
Sincerely,
John A. Gale
  Transportation Regulations  Specialist
  Office of Hazardous Materials  Standards
172.516
Regulation Sections
| Section | Subject | 
|---|---|
| 172.516 | Visibility and display of placards |