USA Banner

Official US Government Icon

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure Site Icon

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Portions of the Department of Transportation are currently in shutdown/furlough status due to a lapse in appropriations. Please continue to monitor this page for updates on DOT’s operating status.

U.S. Department of Transportation U.S. Department of Transportation Icon United States Department of Transportation United States Department of Transportation

Interpretation Response #00-0328 ([HITECH] [Ms. Jackie Brian])

Below is the interpretation response detail and a list of regulations sections applicable to this response.

Interpretation Response Details

Response Publish Date:

Company Name: HITECH

Individual Name: Ms. Jackie Brian

Location State: AR Country: US

View the Interpretation Document

Response text:

February 20, 2001

 

Ms. Jackie Brian                         Ref.  No: 00-0328
Materials Manager
HITECH
P.O. Box 3112
East Camden, AR 71711

Dear Ms.  Brian:

This responds to your November 3, 2000 letter requesting clarification pertaining to the instructions for using the compatibility table for Class I explosive materials under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171 -180).  Specifically, you ask for a clarification of § 177.848(g)(3)(vi) regarding explosive articles in compatibility group G, being loaded with explosive articles in compatibility groups C, D and E.

Your understanding is correct.  Section 177.848(g)(3)(vi) permits you to transport explosive articles in compatibility group G with explosive articles in compatibility groups C, D, and E, provided the compatibility group G articles are not fireworks or those requiring special stowage and further provided that no explosive substances are carried on the same vehicle.  An explosive substance is a material which meets the definition of an explosive as defined by Subpart C of Part 173 of the HMR, and is designed to produce a practical effect by explosion.  An explosive article is a device containing an explosive substance, such as a detonator or a cartridge for weapons.  In the examples you provide in your letter, you may load a truck with a combination of Rocket Motors, UN 0186, 1.3 C and Ammunition Smoke, UN0015,1.2 G. However you may not load a truck with a combination of Ammunition Smoke, UN0015,1.2 G and Hexolite, UN 0118,1.1 D.

I hope this answers your inquiry.

Sincerely,

 

John A. Gale
Transportation Regulations Specialist
Office of Hazardous Material Standards

177.848(g)

Regulation Sections