Metallurgical Evaluation of DOT-E-7042-3000 Cylinder D-99604
Feb 4, 1998
The main purpose of this technical evaluation was to determine the cause of an aluminum cylinder failure in Riviera Beach, FL.
Key Words: SLC, sustain load crack, SCBA, DOT 3AL cylinder with gaseous oxygen, ruptured cylinder, SEM analysis, over pressurize
If you have any technical questions not addressed by this or associated documents, contact Mark Toughiry, 202-366-4545.