Response text:
Apr 2, 1999
Mr. Steve  Farrar                                Ref.  No. 99-0042
  National Technical  Systems
  National Ordnance,  Munitions
  and Environmental Test  Center
  P.O. Box 3315
  East Camden, AR 71701
Dear Mr. Farrar:
This is in response to  your letter of February 10, 1999, requesting clarification on the requirements  for lithiurn batteries under the Hazardous Materials Regulations (HMR; 49 CFR  parts 171-180).
  Specifically you ask  whether a 32 volt lithium battery must be subjected to the tests in the UN  Manual of Tests and Criteria, specifically paragraph 38.3.4.3.2.2.3.
The answer is no. A lithium battery that exceeds the referenced nominal voltage is not subject to those tests. Such a battery would have each cell tested rather than the entire battery.
I hope this information is helpful.
Sincerely,
Delmer F. Billings
  Chief, Standards  Development
  Office of Hazardous  Materials Standards
173.185
Regulation Sections
| Section | Subject | 
|---|---|
| 173.185 | Lithium cells and batteries |