Pipeline Safety: Ineffective Protection, Detection, and Mitigation of Corrosion Resulting From Insulated Coatings on Buried Pipelines

Document
2016-14651.pdf (218.39 KB)

PHMSA is issuing this advisory bulletin to remind all owners and operators of hazardous liquid, carbon dioxide, and gas pipelines, as defined in 49 Code of Federal Regulations (CFR) Parts 192 and 195, to *40399 consider the overall integrity of the facilities to ensure the safety of the public and operating personnel and to protect the environment. Operators are reminded to review their pipeline operations to ensure that pipeline segments that are both buried and insulated have effective coating and corrosion-control systems to protect against cathodic protection shielding, conduct in-line inspections for all threats, and ensure in-line inspection tool findings are accurate, verified, and conducted for all pipeline threats. 

DOT is committed to ensuring that information is available in appropriate alternative formats to meet the requirements of persons who have a disability. If you require an alternative version of files provided on this page, please contact PHMSA-Accessibility@dot.gov.
Effective Date: Tuesday, June 21, 2016
Issued Date: Tuesday, June 21, 2016